Neuroscience basics

Neuron
A nerve cell specialized for passing signals. Dendrites receive input from other neurons, and the axon carries the output to other cells.
Lesson: Cellular components
Action potential / spike
A brief (about one millisecond), all-or-none electrical impulse that travels along the axon. Implanted microelectrodes can record spikes from single neurons. Scalp EEG does not pick them up directly.
Lesson: Cellular components Purves et al., Neuroscience
Synapse
The junction where a neuron passes a signal to another cell, usually through chemical neurotransmitters. Postsynaptic currents in many aligned neurons are the main source of the EEG signal.
Lesson: Cellular components
LFP (Local Field Potential)
The low-frequency part of the voltage recorded by an electrode inside brain tissue. It mostly reflects summed synaptic currents from nearby neurons, while spikes reflect the firing of a few cells.
Buzsáki et al., 2012

Interfaces & recording

BCI (Brain–Computer Interface)
A system that measures brain (or nervous system) activity and translates it into commands for software, a computer, or a prosthetic, sometimes with closed-loop sensory feedback.
Lesson: Introduction to BCI
EEG (Electroencephalography)
Non-invasive recording of electrical brain activity using electrodes on the scalp. Millisecond time resolution and accessible hardware, with lower spatial precision than invasive or MRI methods.
Lab: Read your first EEG signal Primer self-check: EEG
ECoG (Electrocorticography)
An electrode grid placed directly on the cortical surface under the skull during surgery. Delivers much higher signal-to-noise ratio than scalp EEG without penetrating brain tissue.
Primer self-check: Intracranial EEG
sEEG (Stereo-electroencephalography)
Thin depth electrodes implanted into targeted brain structures, widely used clinically to localize epileptic seizures and increasingly studied for speech and motor BCIs.
Primer self-check: Intracranial EEG
Utah array
A small silicon grid of up to 100 microelectrodes (10 × 10), each about 1 to 1.5 mm long, implanted into the cortex. It records spikes and LFPs and has been used in most implanted human BCI studies, including BrainGate.
Lesson: Emerging technologies BrainGate
MEG (Magnetoencephalography)
Non-invasive measurement of tiny magnetic fields generated by neuronal currents. Combines EEG-like millisecond timing with sharper spatial localization inside a shielded room (SQUID or wearable OPM sensors).
Primer self-check: MEG
fNIRS (Functional Near-Infrared Spectroscopy)
Wearable optical brain imaging that uses near-infrared light to track blood oxygenation changes in the cortex. Slower than EEG, but immune to electrical line noise.
Primer self-check: fNIRS
fMRI (Functional Magnetic Resonance Imaging)
Non-invasive whole-brain imaging that measures blood-oxygen-level-dependent (BOLD) signals at millimeter spatial resolution, with temporal resolution on the order of seconds.
Lab: Explore MRI slices and BOLD timing Primer self-check: fMRI
PET (Positron Emission Tomography)
Imaging that tracks a weakly radioactive tracer in the body, such as a glucose analog to measure metabolism or a ligand that binds to receptors. It involves ionizing radiation, and its time resolution is measured in minutes.
Primer self-check: PET NIBIB: Nuclear medicine
EMG (Electromyography)
Recording of electrical muscle activity (often at the wrist or forearm), used in non-invasive neuromotor interfaces and myoelectric prosthetics.
International 10-20 system
The standard way to place and name EEG electrodes at 10% or 20% of the distances between skull landmarks (nasion, inion, preauricular points). The letter gives the region (Fp, F, C, P, O, T), odd numbers are on the left, even numbers on the right, and "z" on the midline.
Lesson: Introduction to BCI
Montage
The word has two meanings. In software such as MNE-Python, it is the set of electrode positions on the head. In clinical EEG, it is how electrodes are combined into displayed channels (bipolar or referential montage).
MNE: Sensor locations
Reference electrode
EEG measures voltage differences, so each channel is expressed relative to a reference (a mastoid, Cz, or the average of all electrodes computed afterward). Changing the reference changes the waveforms, so always report it.
MNE: Setting the EEG reference
Ground electrode / DRL
An electrode that ties the person to the amplifier’s common circuit to reduce interference that appears on all electrodes at once. In a driven right leg (DRL) design, the circuit actively feeds an inverted copy of that common signal back to the body.
BioSemi: CMS and DRL
Electrode impedance
Opposition to current flow at the electrode–skin contact, measured in kilohms (kΩ). Low impedance that is similar across electrodes reduces noise. The acceptable value depends on the amplifier, so follow the manufacturer’s guidance.
Lesson: EEG experimental protocol
Artifact
Any part of a recording that does not come from the brain: blinks and eye movements, muscle tension, heartbeat, power-line noise (50 or 60 Hz), or a moving electrode. Artifacts can be larger than the brain signal.
Lab: Spot artifacts and compare EEG filters Lesson: Preprocessing

Stimulation & neuromodulation

TMS (Transcranial Magnetic Stimulation)
Focused magnetic pulses delivered through the skull to modulate activity in a targeted cortical region. Widely used in neuroscience research and clinical depression treatment.
Primer self-check: TMS
tDCS / tACS (Transcranial Direct / Alternating Current Stimulation)
Low-intensity electrical currents applied via scalp electrodes to shift cortical excitability (tDCS) or entrain neural oscillations (tACS).
Primer self-check: Transcranial electrical stimulation
tFUS / LIFU (Transcranial Focused Ultrasound)
Non-invasive technique focusing low-intensity ultrasound waves through the skull to modulate deep or superficial brain structures with millimeter spatial precision.
Primer self-check: Focused ultrasound
DBS (Deep Brain Stimulation)
Implanted electrodes connected to a pulse generator to treat conditions such as Parkinson’s disease, essential tremor, and refractory epilepsy. Adaptive (closed-loop) systems adjust stimulation using sensed neural signals.
Primer self-check: DBS

Signals & paradigms

Neural oscillations (delta, theta, alpha, beta, gamma)
Rhythmic brain activity measured with EEG or MEG, grouped into frequency bands (~1 Hz to >30 Hz) linked to sleep, attention, visual rest, movement, and cognitive processing.
Lesson: Neural oscillations
ERD / ERS (Event-Related Desynchronization / Synchronization)
A decrease (ERD) or increase (ERS) in power in a frequency band relative to a baseline, linked to an event. For example, mu and beta rhythms drop over sensorimotor cortex during real or imagined movement.
Lesson: Neural oscillations Pfurtscheller & Lopes da Silva, 1999
ERP (Event-Related Potential)
A time-locked electrical brain response to a specific sensory, cognitive, or motor event, typically revealed by averaging across repeated trials.
Lab: Reveal an EEG response by averaging trials Lesson: Event-related potentials
P300
A positive voltage peak occurring ~300 ms after a rare or attended target stimulus (the oddball paradigm), classic in BCI spellers.
Lab: Reveal an EEG response by averaging trials
SSVEP (Steady-State Visual Evoked Potential)
An oscillatory visual-cortex response locked to the exact flicker frequency of an attended visual target, enabling fast, high-accuracy non-invasive selection.
Lesson: EEG applications
Motor imagery (MI)
Mentally rehearsing a movement (such as left vs. right hand) without physically moving, producing characteristic shifts in sensorimotor mu and beta rhythms.
Neurofeedback
A method that shows people a real-time measure of their own brain activity (as a sound, image, or game) so they can learn to change it. Evidence of benefit varies widely by application.
Lesson: EEG applications Sitaram et al., 2017
Closed loop
A system that adjusts its output in real time based on the signals it measures. Neurofeedback, BCIs with feedback, and adaptive deep brain stimulation are closed-loop. In an open-loop system, the output does not depend on the measurement.
Lesson: Emerging technologies

Signal processing & decoding

Sampling rate
The number of measurements taken per second on each channel, in hertz (Hz). Many consumer EEG headsets sample at 128 to 512 Hz. It limits which frequencies you can analyze.
Lesson: Consumer EEG headsets
Nyquist frequency
Half the sampling rate: the highest frequency a digital signal can represent. Faster activity folds back onto lower frequencies (aliasing), which is why an anti-aliasing filter is applied before digitization.
Lesson: Preprocessing
Fourier transform & power spectrum
The Fourier transform breaks a signal into sine waves of different frequencies. The power spectrum shows how much power each frequency holds. For EEG it is often estimated with Welch’s method.
Lesson: Neural oscillations
Band power
Signal power within a frequency band, such as alpha (8 to 12 Hz). It can be absolute or relative, meaning a share of total power. It is one of the most common BCI features.
Lab: EEG capstone with MNE-Python
Filters (high-pass, low-pass, notch)
A high-pass filter removes slow changes below a cutoff frequency, and a low-pass filter removes fast changes above one. A notch filter removes a narrow band, often 50 or 60 Hz power-line noise. Any filter can also distort the signal you care about.
Lab: Spot artifacts and compare EEG filters MNE: Background on filtering
Epoch
A segment of signal cut around an event, for example from 200 ms before to 800 ms after a stimulus. Epochs let you average trials or classify each one.
Lab: Reveal an EEG response by averaging trials MNE: The Epochs data structure
SNR (Signal-to-Noise Ratio)
The ratio between the amplitude or power of the signal you want and that of the noise. Averaging N trials reduces random noise by a factor of the square root of N, which is how event-related potentials emerge.
Lab: Reveal an EEG response by averaging trials
ICA (Independent Component Analysis)
A source-separation method that splits channels into statistically independent components. It is mostly used to find and remove components caused by blinks or the heartbeat.
Lesson: Preprocessing MNE: Artifact correction with ICA
CSP (Common Spatial Patterns)
Spatial filters learned from labeled trials that maximize signal variance for one class while minimizing it for the other. Combined with log-variance features and LDA, it is a classic two-class motor imagery pipeline.
MNE: Decoding with CSP Ramoser et al., 2000
Riemannian geometry (covariance-based decoding)
An approach that represents each trial by its spatial covariance matrix and compares these matrices with a distance suited to their geometry. These methods are simple to calibrate and perform strongly in BCI benchmarks.
pyRiemann Congedo et al., 2017
LDA (Linear Discriminant Analysis)
A linear classifier that finds the projection that best separates classes relative to their spread. Fast and robust, often with shrinkage regularization, it remains a baseline for P300 and motor imagery.
scikit-learn: LDA
Cross-validation
Split the data into parts, train the model on some, test it on the parts it has not seen, and repeat. With EEG, keep blocks, sessions, or people separate between training and testing, because neighboring trials resemble each other.
Lesson: Machine learning for BCI scikit-learn: Cross-validation
Chance level
The accuracy expected from random guessing, such as 50% for two balanced classes. With few trials, a classifier can beat this by luck. A permutation test or a binomial threshold tells you whether a result is really above chance.
Combrisson & Jerbi, 2015
Transfer learning / cross-subject decoding
Reusing data or a model from other people or sessions to shorten calibration for a new user. Cross-subject evaluation tests a model on a person left out of training.
MOABB: CrossSubjectEvaluation
EEG foundation model
A large neural network pretrained, often self-supervised, on thousands of hours of EEG from many datasets, then fine-tuned for specific tasks. For example, LaBraM (2024) was pretrained on about 2,500 hours of EEG.
Jiang et al., 2024: LaBraM

Tools, standards & regulation

LSL (Lab Streaming Layer)
Open-source networking protocol for streaming and time-synchronizing real-time biosignals (EEG, event markers, eye tracking) across devices and languages.
LSL documentation
XDF (Extensible Data Format)
An open file format that stores several time-series streams with their timestamps and XML metadata. It is the format written by LabRecorder, the LSL recorder.
XDF specification
BIDS (Brain Imaging Data Structure)
Open community standard for organizing neuroimaging and electrophysiology datasets (MRI, EEG-BIDS, MEG, iEEG, fNIRS) so pipelines and datasets are shareable and reproducible.
BIDS website
OpenNeuro
A free platform for sharing neuroimaging and electrophysiology data (MRI, MEG, EEG, iEEG, PET). Datasets are uploaded in BIDS format.
OpenNeuro
MNE-Python
The flagship open-source Python library for preprocessing, visualizing, source-localizing, and analyzing MEG, EEG, and sEEG data.
MNE-Python website
MOABB (Mother of All BCI Benchmarks)
Open-source project maintained by the NeuroTechX community that bundles public EEG datasets and reproducible evaluation pipelines for benchmarking BCI algorithms.
MOABB website
REB / IRB (Research Ethics Board)
A committee that reviews and approves research involving people before it starts, then monitors it. In Canada, REBs follow the TCPS 2. In the United States, they are called institutional review boards (IRBs).
TCPS 2 (2022)
Neuroethics
The field that studies the ethical, legal, and social questions raised by neuroscience and neurotechnology, such as privacy, autonomy, fair access, and non-clinical uses. In 2019 the OECD adopted a Recommendation on Responsible Innovation in Neurotechnology.
Primer self-check: Neuroethics OECD Recommendation
510(k), De Novo, PMA & IDE
Core US FDA medical-device pathways: 510(k) (substantial equivalence to a predicate), De Novo (novel low-to-moderate-risk devices), PMA (high-risk devices such as implants), and IDE (permission to run a clinical study).
FDA: Selecting the correct submission
CE marking & MDR (EU)
The EU Medical Device Regulation (EU) 2017/745 (MDR) has applied since May 2021. The CE marking shows that a device conforms. Annex XVI also covers brain stimulation equipment without a medical purpose that applies currents or fields through the skull.
Regulation (EU) 2017/745 on EUR-Lex
Health Canada medical device licensing
The Medical Devices Regulations sort devices into Classes I (lowest risk) to IV (highest risk). A Class II, III, or IV device can be imported or sold in Canada only if its manufacturer holds a medical device licence.
Medical Devices Regulations (SOR/98-282)
Neurorights & neural data privacy
Legal and ethical frameworks focused on mental privacy, informed consent, and cognitive liberty as neural recording and decoding become more capable and widespread.
Safety & ethics

Keep learning

Work through our 15 free lessons on EEG and BCI fundamentals, or read our guide to neurotech safety, privacy, and regulation.