Find a blink and a jaw clench. Try two filter settings and see what they attenuate.
Look for a large deflection near 1 s and fast activity between 2.6 and 3.2 s. Predict which one a low-pass filter will attenuate more.
Select 30 Hz and compare the traces. What remains of the blink and the 10 Hz rhythm?
Try 5 Hz. The trace looks smoother. How much of the rhythm you wanted does the filter pass?
Compare raw and filtered traces
Raw trace
+900−90
01234
Amplitude (µV)Time (s)
Processed trace
+900−90
01234
Amplitude (µV)Time (s)
Amplitude passed at 10 Hz
100%
Absolute peak around the blink
78 µV
RMS amplitude during the jaw clench
16 µV
About this simulation
The simulated signal combines a 10 Hz rhythm, a slow blink deflection, and fast muscle activity. A symmetric FIR filter is applied offline. The percentage at 10 Hz is the filter gain for a sinusoid at that frequency. RMS summarizes the trace amplitude in a specified window.
Why compare with the raw trace?
A low-pass filter attenuates fast changes. A slow artifact can remain, and cutting higher frequencies can also remove part of the signal you care about. Inspect the raw trace and choose processing based on the question you want to answer.