← Learn neurotechnology
20–30 minutes · Basic Python
EEG capstone: Check whether a result holds up
Reproduce the first EEG lab with MNE-Python. Change the analysis window and explain how far your conclusion reaches.
Compare eyes-open and eyes-closed recordings
- Plot Fp1 and O1 for two resting-state clips from the same participant.
- Calculate O1’s relative alpha power in the 8–12 Hz band. Compare conditions across several clips.
- Write three sentences covering your result at 18 seconds, what changes across clips, and what to test before generalizing.
Open the notebook in Jupyter or Colab. The first run downloads about 2.5 MB of public data.
Check my interpretation
At 18 seconds, O1 has about 31% relative alpha power with eyes open and 71% with eyes closed. The size of the gap varies across clips. An analysis across participants with criteria defined in advance could test whether the finding generalizes.