15 minutes · Simulated data
Compare neuromodulation methods on one head
Aim at a superficial or a deep target in a real head model and compare TMS, tDCS or tACS, temporal interference and focused ultrasound.
Simulation only. Nothing here was measured on a person. The fields are computed in the SimNIBS “ernie” head model. They are not a dose or a safety limit.
TMS, transcranial electrical stimulation and focused ultrasound act on the brain without surgery. They do not measure anything: they send an electric field or a pressure wave into tissue. This lab puts each method on the same head and the same target to compare how far the field spreads and how deep it reaches.
The ultrasound helmet is based on the clinical device used at sites such as Sunnybrook Health Sciences Centre in Toronto, which the Focused Ultrasound Foundation named Canada’s first focused ultrasound Centre of Excellence in 2016. According to Sunnybrook, its team published the first study to use focused ultrasound to treat essential tremor in 2012, and in 2015 was the first to open the blood–brain barrier this way. In 2018, Lipsman and colleagues described a phase 1 trial there that opened this barrier in five people with Alzheimer’s disease, using a 1024-element InSightec ExAblate Neuro device at 220 kHz.
- Choose TMS and the superficial target (hand motor cortex). Note the share of the peak that reaches the target, then switch to the deep target (thalamus).
- Switch to tDCS. Compare the volume above half the peak with the TMS one. What do you notice about the strength, in V/m?
- Try temporal interference. Where is the envelope maximum compared with the electrodes?
- Switch to the ultrasound helmet with the deep target. Turn skull correction on and off. Then compare with the single transducer.
Compare the methods
Colour: field divided by its peak in the brain (0 to 1, saturated above). The cross marks the target. The skull is pale grey. L and R: the person’s left and right.
Measurements in the brain
- Peak in the brain
- 1.50 V/m per A/µs
- At the target, as a share of the peak
- 0.48
- Volume above half the peak
- 17.7 cm³
- Deepest point of that volume
- 18.5 mm
- Distance from the maximum to the target
- 10.5 mm
Coverage
Top-down view, nose up. The circle is the head outline. The helmet, larger than the head, is shrunk to fit the drawing.
At a glance · TMS (figure-8 coil)
- What it does
- A brief current in the coil makes a changing magnetic field, which induces an electric field in the brain. If it is strong enough, it can make neurons fire.
- Elements in this simulation
- One 70 mm figure-8 coil (SimNIBS Magstim model), 4 mm from the scalp.
- Frequency
- One pulse. The calculation uses a current change of 1 A/µs; the field is proportional to this value.
- What limits depth and resolution
- The field is strongest at the cortical surface and falls with depth. Coils that reach deeper also spread the field (depth–focality trade-off, Deng et al. 2013).
- What full coverage buys
- With one coil, moving the focus means moving the coil.
What these maps do not tell you
A simulated field is not a dose or a safety assessment, and it does not say whether neurons respond. Ultrasound can act through mechanical and thermal effects. The ITRUSST consensus on the safety of transcranial ultrasound stimulation describes these risks with the mechanical index and the temperature rise, which this lab does not calculate.
How the maps were computed
SimNIBS 4.6.0 computes the electric field with finite elements in the “ernie” mesh, using its default conductivities. BabelBrain v0.8.9, with the BabelViscoFDTD solver, simulates ultrasound in the same model from the charm segmentation, without a CT scan, at 6 points per wavelength. The targets come from MNI coordinates mapped to ernie: (−37, −21, 58) for the hand and (−12, −18, 8) for the thalamus.
Peak: 99.9th percentile of the electric field in grey and white matter, or the maximum pressure for ultrasound. Target: mean in a 3 mm sphere. Depth: measured below the outer brain surface.
Build scripts in the repository: scripts/build-learn-neuromod.py, scripts/learn-neuromod/
Key points
In this head, the electric fields of TMS and tES are strongest near the cortex and spread over tens to hundreds of cubic centimetres. With this montage, the temporal interference envelope is about as widespread as the tDCS field. The ultrasound helmet concentrates pressure into less than one cubic centimetre, even at the thalamus, and skull correction brings the maximum to about 1 mm from the target instead of 3 to 4 mm.
Sources and software
- SimNIBS (GPL-3.0), Thielscher et al. 2015 ↗ · DOI ↗
- charm segmentation, Puonti et al. 2020 ↗
- SimNIBS example dataset, ernie (CC BY-NC 4.0) ↗
- BabelBrain (BSD-3), Pichardo 2023 ↗ · DOI ↗
- BabelViscoFDTD (BSD-3) ↗
- Temporal interference, Grossman et al. 2017 ↗
- TMS depth–focality trade-off, Deng et al. 2013 ↗
- Lipsman et al. 2018, Nature Communications ↗
- Sunnybrook Centre of Excellence in Focused Ultrasound ↗
- Sunnybrook focused ultrasound lab, with photos ↗
- Sunnybrook Harquail Centre for Neuromodulation ↗
- ITRUSST consensus on biophysical safety ↗